Class II Type A2 Biosafety Cabinet Manufacturer | Factory Direct for Laboratory & Life Science Suppliers

 

Our Class II Type A2 Biosafety Cabinets are engineered to provide reliable personnel, product, and environmental protection during biological, cell culture, clinical, pharmaceutical, and biotechnology research.

 

Operating with an active inward airflow barrier combined with vertical HEPA-filtered laminar air, each cabinet delivers validated containment in full compliance with international laboratory safety standards.


We specialize in OEM/ODM production and wholesale supply for global laboratory equipment distributors, tender contractors, and private-label brands, offering flexible configurations, local voltage setups, and comprehensive technical documentation.

 
  • Biosafety Cabinet and Laminar Air Flow
    HAMECC offers a complete range of laboratory furniture systems for global customers, including worktops, lab workbenches,Biosafety Cabinet And Laminar Air Flow, fume hoods exhaust systems,service
  • Fume Hood Biosafety Cabinet
    1, Fume Hood Biosafety Cabinet has motorized front window.2, Time reserve function.3, HEPA filter life and UV life indicator4, Automatic air speed adjustable with filter block.5, With memory function
 
Product Types Selection

 

Model Code

Nominal Width

External Dimensions (W x D x H)

Work Area Dimensions (W x D x H)

Inflow / Downflow Velocity

Exhaust Air Ratio

BSC-0900A2

3 ft (0.9 m)

1100 x 770 x 2150 mm

900 x 600 x 660 mm

0.51 m/s (100 fpm) / 0.33 m/s (65 fpm)

70% Recirculated / 30% HEPA Exhaust

BSC-1200A2

4 ft (1.2 m)

1400 x 770 x 2150 mm

1200 x 600 x 660 mm

0.51 m/s (100 fpm) / 0.33 m/s (65 fpm)

70% Recirculated / 30% HEPA Exhaust

BSC-1500A2

5 ft (1.5 m)

1700 x 770 x 2150 mm

1500 x 600 x 660 mm

0.51 m/s (100 fpm) / 0.33 m/s (65 fpm)

70% Recirculated / 30% HEPA Exhaust

BSC-1800A2

6 ft (1.8 m)

2000 x 770 x 2150 mm

1800 x 600 x 660 mm

0.51 m/s (100 fpm) / 0.33 m/s (65 fpm)

70% Recirculated / 30% HEPA Exhaust

 

Technical Specifications

 

Parameter

Specification

Why It Matters to Buyers

Cabinet Type

Class II Type A2

Provides personnel, product, and environmental protection for applicable microbiological and cell culture applications.

Inflow Velocity

0.51 m/s (100 fpm)

Creates the inward airflow barrier at the front opening to help prevent contaminated air from escaping toward the operator.

Downflow Velocity

0.33 m/s (65 fpm)

Provides controlled vertical airflow across the work zone to support product protection and stable cabinet operation.

Supply & Exhaust Filtration

Dual H14 HEPA Filters; ≥99.995% at MPPS / ≥99.99% at 0.3 μm

Dual filtration helps control airborne particles in both the supply and exhaust air paths.

Filter Leak Testing

EN 1822 / IEST-RP-CC001.4 compliant

Provides a defined basis for evaluating HEPA filter efficiency and integrity rather than relying only on a nominal filter grade.

Work Chamber Material

1.2 mm SUS304 Stainless Steel, non-porous and seamless

Stainless steel provides a smooth, corrosion-resistant work surface that is easier to clean and disinfect during routine laboratory use.

Outer Cabinet Shell

Heavy-gauge cold-rolled steel with antibacterial powder coating

Provides a rigid external structure while the powder-coated surface improves resistance to routine environmental wear.

Front Window Sash

6 mm toughened safety glass, motorized or manual option, with anti-UV protection

Toughened glass provides improved mechanical safety; motorized or manual operation allows the cabinet to be configured for different user requirements.

Lighting System

Energy-efficient LED; ≥1,000 lux

Provides sufficient illumination across the work area for handling samples, instruments, and containers with better visibility during extended procedures.

Operating Noise

≤62 dB(A) under standard operating conditions

Helps reduce operator fatigue and makes the cabinet more suitable for laboratories where personnel work beside the equipment for extended periods.

Control System

Microprocessor-controlled LCD display

Provides real-time operating information, including airflow velocity, filter lifespan, sash status, and working pressure.

Alarm Protection

Audible & visual alarms for Low Airflow, Sash Height Violation, Blower Fault, and Filter Lifetime Expiry

Gives operators an immediate indication when key operating conditions move outside the defined range or maintenance is required.

Electrical Supply

110V/60Hz, 220V/50Hz, or 230V/60Hz adaptable

Supports different electrical requirements for international distribution and reduces the need for separate cabinet platforms for different markets.

Base Stand

Fixed, manual height-adjustable, or motorized height-adjustable; heavy-duty lockable casters and leveling feet

Allows distributors to configure the cabinet for different laboratory layouts and operator-height requirements while providing stable positioning during use.

Standard Accessories Included

Waterproof internal sockets (2 pcs), UV lamp with interlock timer, gas tap, and vacuum tap

 

Controlled Airflow System & Containment Performance

Precision Airflow Barrier:

High-efficiency ECM blower motors dynamically balance inflow and downflow performance. A calibrated 0.51 m/s (100 fpm) inflow barrier prevents contaminated room air from entering the work zone while protecting the operator from internal aerosols.

H14 High-Efficiency Filtration:

Integrated supply and exhaust H14 HEPA filters feature polyurethane gasket seals to eliminate bypass leaks. All recirculated and exhausted air passes through validated multi-stage filtration to maintain ISO Class 5 cleanliness within the work chamber.

productcate-600-450
productcate-600-450

Ergonomic Work Environment:

Designed with a 10-degree sloped front glass window to minimize glare and reduce fatigue during extended laboratory procedures. High-intensity LED illumination ensures uniform visibility across the entire stainless steel work surface.

Cleanroom-Grade Interior Construction:

The internal work area features coved (rounded) internal corners, a removable multi-piece SUS304 work tray, and a built-in stainless steel drain pan. Smooth surfaces permit rapid, thorough decontamination using standard disinfectants, alcohol, or vaporized hydrogen peroxide (VHP).

 

 

Factory Quality Control & Compliance Documentation

Every unit undergoes rigorous internal testing prior to dispatch to ensure compliance with NSF/ANSI 49, EN 12469, and CE directives:
PAO / DOP Filter Integrity Leak Testing


Inflow & Downflow Airflow Velocity Profiling


Airflow Smoke Pattern Visualization Testing


Electrical Safety Inspection (Hi-Pot, Earth Grounding & Insulation Resistance)


Acoustic Noise & Mechanical Vibration Analysis


Supplied Documentation: Each shipment includes individual Factory Acceptance Test (FAT) reports, product calibration records, CE Declaration of Conformity, English user manuals, and wiring schematics.

Biosafety Cabinet and Laminar Air Flow

 

OEM & Private Label Solutions

We provide complete manufacturing flexibility to help distributors, regional dealers, and EPC project contractors meet specific local market demands:

 

Custom Electrical & Plug Standards:

Configured for US, EU, UK, Australian, or universal plug and voltage requirements.

 

Private Labeling & Branding:

Custom screen-printed logos, branded membrane keypads, customized serial nameplates, and distributor-branded user manuals.

Accessory & Canopy Options:

Thimble duct connections for external canopy exhaust, motorized front sashes, and customized utility service ports (gas, nitrogen, water, vacuum).

Export-Safe Packaging:

Encased in heavy-duty, fumigation-free wooden crates reinforced with shock-absorbing foam lining and moisture barriers, engineered for safe ocean, air, and LCL transit.

Spare Parts & After-Sales Support:

Full supply-chain availability for replacement H14 HEPA filters, ECM blowers, control PCBA units, UV tubes, and pressure sensors with guaranteed 10-year spare parts continuity.

 

Typical Applications
 

Microbiology & Molecular Biology Research

Cell Culture & Tissue Engineering Laboratories

Clinical Diagnostic & Hospital Testing Centers

Pharmaceutical Quality Control & Cleanroom Operations

Biotechnology & Vaccine Development Facilities

University Teaching & Research Laboratories

 

FAQ

 

Q: What is the main difference between a Class II Type A2 and Type B2 Biosafety Cabinet?

A: Class II Type A2 cabinets recirculate 70% of the HEPA-filtered air within the work zone and exhaust 30% back into the laboratory or through an optional canopy duct. They are ideal for general microbiological and cell culture work without volatile toxic chemicals. Class II Type B2 cabinets exhaust 100% of the air outdoors via dedicated hard-duct ventilation with zero internal recirculation, making them suitable for work involving trace volatile chemicals or radionuclides.

Q: Are your Class II A2 cabinets certified according to NSF/ANSI 49 and EN 12469?

A: Yes. Our cabinets are engineered, tested, and manufactured in accordance with NSF/ANSI 49, EN 12469, and CE safety standards. Every individual unit undergoes factory containment, airflow, and filter integrity testing, and is delivered with a complete Factory Acceptance Test (FAT) report and Declaration of Conformity.

Q: How often do the H14 HEPA filters need to be replaced?

A: HEPA filter life depends on room cleanliness and operating hours, but under standard laboratory conditions, filters typically last between 3 to 5 years. The onboard microprocessor control system monitors filter loading and pressure differentials in real time, alerting operators via visual and audible alarms when filter replacement is required.

Q: Can you provide private label / OEM services for our company?

A: Yes. We fully support laboratory equipment distributors, tender contractors, and brand owners. Our OEM capabilities include customized logo printing, branded control panels and membrane keypads, customized serial plates, distributor-branded user manuals, and tailored outer cabinet color schemes subject to minimum order quantities (MOQ).

Q: Do you supply spare parts for long-term maintenance?

A: Absolutely. We maintain a guaranteed 10-year supply chain for critical replacement components, including H14 HEPA/ULPA supply and exhaust filters, ECM blowers, control PCBA boards, pressure sensors, motorized sash assemblies, and UV lamps. Spare parts kits can be included directly in your bulk shipment.

Q: Does factory inspection replace local field certification after installation?

A: No. Factory testing confirms that the cabinet leaves our production line in optimal operational condition. Standard laboratory safety protocols require field certification (testing inflow/downflow velocities and HEPA filter integrity) on-site after transportation and installation, as well as after any major service or relocation.

 

Request a Distributor Wholesale Quote
 

Sourcing Class II Biosafety Cabinets for local tenders, hospital projects, or your distribution catalog? Contact our engineering team for competitive factory-direct pricing, datasheets, and customization details.

Please include the following in your inquiry:

Required Nominal Widths: 3 ft / 4 ft / 5 ft / 6 ft

Target Quantity & Delivery Timeline

Voltage / Frequency Standards (e.g., 220V/50Hz, 110V/60Hz)

OEM / Private Labeling Requirements: Yes / No

Required Accessories (Base Stand, UV Lamp, Canopy Exhaust, Utility Ports)

Contact Us Today to Receive Your Custom B2B Quotation & Technical Datasheet Package.

We're well-known as one of the leading biosafety cabinet manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to buy customized biosafety cabinet made in China here from our factory.

Fume Hood Biosafety Cabinet, biosafety cabinet, Biosafety Cabinet and Laminar Air Flow
Send Inquiry