Laboratory Fume Hoods & Complete Exhaust Solutions
Engineering Safe, Compliant, and Custom Air Handling for Global Laboratories
HAMECC designs and manufactures high-performance laboratory fume hoods for chemical processing, research, pharmaceuticals, and industrial testing environments. Rather than treating fume hoods as standalone furniture, we engineer each enclosure as an integral node of your laboratory's HVAC system.
From benchtop units to walk-in containment enclosures, HAMECC coordinates the hood structure, internal baffles, sash movement, PP ductwork, and exhaust blowers to guarantee certified containment and operational efficiency.
-
Fume Exhaust HoodHAMECC, a lead supplier of laboratory equipment. HAMECC offers various Fume Exhaust hood, including ducted and ductless models, designed for multiple laboratory applications.CERTIFICATION:
-
Benchtop Chemical Fume HoodHAMECC, a lead supplier of laboratory equipment. HAMECC offers various Benchtop chemical fume hoods, including ducted and ductless models, designed for multiple laboratory applications.CERTIFICATION:
-
Ductless Fume Hood for LabDuctless Fume Hood For Lab offer a versatile and effective solution for managing hazardous fumes and vapors.
-
Walk in HoodsThe ABJ series Walk in hoods is mainly used for automatic detection of visible impurities and sealing
-
Laboratory Chemical HoodA laboratory chemical hood (often called a fume hood) is an essential safety device designed to protect laboratory personnel, the environment, and experiments from hazardous airborne chemicals,
-
Benchtop Ductless Fume HoodThe ABJ series Benchtop ductless fume hood is mainly used for automatic detection of visible impurities and sealing.It ensures safety with real-time VOC monitoring and efficient filtration. Featuring
-
Acid Digestion Fume HoodPerchloric Acid digestion fume hood overcomes the shortcomings of traditional fume hoods, which are prone to rust, yellowing, and cracking in high-temperature, concentrated acid environments, and
-
Fume Hood with BlowerHAMECC ADVANTAGE HAMECC , a lead supplier of laboratory Fume Hood With Blower. HAMECC offers various fume hood with blower, including axial flow blower, mixed flow blower, and centrifugal blower to
-
Acid Fume HoodAcid fume hood are widely used in pharmaceutical production, food processing industry and various scientific research institutions, electronic and electrical production and new energy industries.
Product Classification Framework:
Ducted Exhaust Systems
Ductless Filtered Enclosures
Benchtop Chemical Hoods
Floor-Mounted / Walk-In Enclosures
Acid Digestion & High-Corrosion Hoods
Variable Air Volume (VAV) Integrated Systems
Comparison & Selection
|
Hood Type |
Primary Application |
Exhaust / Filtration |
Best Suited For |
|
Ducted Fume Hood |
General chemical handling, toxic vapors, high heat |
External roof/wall exhaust |
Facilities with dedicated ductwork & exhaust HVAC |
|
Ductless Fume Hood |
Light chemical mixing, low-volume vapors |
Internal carbon / HEPA filters |
Existing rooms without duct access; lower chemical volume |
|
Benchtop Hood |
Space-constrained chemical testing |
Ducted or Ductless setup |
Mounting on existing lab casework or modular benches |
|
Walk-In Hood |
Large analytical equipment, pilot scale-up |
High-volume external exhaust |
Heavy machinery, distillation columns, roll-in carts |
|
Acid Digestion Hood |
Trace metal analysis, hot acid boiling |
Dedicated PP duct + Washdown |
Concentrated HCl, HF, HNO3, HClO4 environments |
Engineered for Certified Containment: ASHRAE 110 & SEFA
A safe fume hood relies on precise aerofoil dynamics, baffle positioning, and stable face velocity, not just fan power.
Standard Face Velocity:
Designed to maintain 0.5 m/s (100 FPM) at standard working sash height.
01
Tested Standards:
Evaluated in accordance with ASHRAE 110 (Face Velocity Profile, Smoke Flow Visualization, and Tracer Gas Containment Test).
02
Compliance Standards:
Manufactured to conform with SEFA 1 (Fume Hoods) and SEFA 8M (Laboratory Casework).
03
Multi-Stage Testing Support:
Factory Acceptance Testing (AM - As Manufactured), Site Installation Verification (AI - As Installed), and Operational Certification (AU - As Used).
04

Material Selection Guide:
Exterior Body: 1.2mm Cold-Rolled Steel + Epoxy Powder Coating (High impact resistance, structural rigidity)
Internal Liners:
Compact Laminate: General chemistry, easy-clean
Polypropylene (PP): High-concentrate acids, HF
Stainless Steel 304/316: Solvents, high heat
Sash & Glazing: 6mm Clear Tempered Glass / Explosion-Proof Polycarbonate
Turnkey HVAC Integration: Ductwork & Blowers
Mismatched duct static pressure or underpowered blowers undermine fume hood containment. HAMECC provides end-to-end exhaust package integration:
PP Exhaust Blowers:
Anti-corrosive polypropylene centrifugal fans engineered for acidic exhaust.
PP Ducting & Fittings:
Corrosion-proof round and rectangular ductwork systems customized to your building layout.
VAV / CAV Controls:
Airflow control valve integration (Variable Air Volume) to reduce building energy consumption by up to 60%.
OEM / Custom Manufacturing & Global Project Delivery
Backed by a 20,000 m2 manufacturing facility with 15,000 m2 of specialized workshops, HAMECC delivers custom laboratory enclosures to over 32 countries.
Customization Options Available:
Dimensions:
Custom width (1200mm to 2400mm+), internal working depth, and height adjustments.
Service Fixtures:
Remote-control water/gas valves, cup sinks, vacuum outlets, and explosion-proof electrical sockets.
Storage Cabinets:
Base storage configured for flammables, acids (PP lined), or general lab supplies.
Procurement Checklist: How to Request a Quote
To assist our engineering team in calculating exhaust static pressure, required face velocity, and cabinet dimensions, please share:
Laboratory Layout / Architectural CAD Drawing (If available)
01
Chemical List & Operating Temperatures (e.g., HF, HClO4, Solvents)
02
Preferred Dimensions (Width x Depth x Height)
03
Exhaust Configuration (Existing HVAC connection OR require HAMECC Blower + PP Duct package)
04
Utility Requirements (Gas, Water, Power Phase/Voltage)
05
FAQ
We're well-known as one of the leading fume hoods manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to buy customized fume hoods made in China here from our factory.